Product name: HC210 cable fault tester
Category: High-voltage equipment comprehensive test series

Detailed introduction

Product introduction

HC210 cable fault tester caters to the rapid development of industrial-grade power industry solutions and the IT era. The limitations of the original cable fault tester are systematized with industrial control embedded computer platform system, network service business, and USB communication technology, which improves the instrument’s use function and utilization value as well as convenient on-site environment operation.

Functional features

◆ Adopting industrial control embedded computer platform system, the whole system will consist of three parts: fault test, path detection, and precise fixed point. It is powered by lithium battery, easy to carry and convenient to test;

◆ Adopting 12.1-inch LCD large screen and touch mouse, full computer XP operating platform integrated software, completely bid farewell to the era of cable instrument single-chip microcomputer, and equipped with cable fault test software and cable data management software.

◆ Adopting USB communication interface, the acquisition signal is stable, the host can automatically select five sampling frequencies from the lowest 6.25MHz to the highest 100MHz, and the adaptive pulse width can meet the test requirements of cables of different lengths, reduce the rough measurement error, and improve the test accuracy.

◆ Powerful waveform processing function and network service function, the test waveform can be compressed and expanded arbitrarily, and two waveforms closer to the standard are randomly displayed on the same screen for you to accurately compare and analyze, reducing errors;

◆ The newly developed intelligent combined sampler replaces the cumbersome on-site wiring, has the characteristics of intuitive waveform, easy analysis, complete isolation from high voltage, and absolute safety for the host and operators.

Technical parameters

Test distance Not less than 40km
Shortest test distance (blind zone) 5-10m
Precise positioning error ±0.2m
Test Error System error is less than ±1%
Resolution V/50m V is the wave propagation speed m/μs and the software cursor is 0.15 meters.
Instrument sampling frequency 6.25MHz, 12.5MHz, 25MHz, 50MHz, 100MHz, (adaptive pulse width)
Power supply and power consumption AC220V±10%  15W   DC12V(7AH) No more than 20W
Standby time It can be used continuously for about 3.5 hours.